You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Current »

To enable the "tab" function after scanning a barcode on a Honeywell device, you can follow these steps:

  1. Open the Settings App:

    • Swipe up from the bottom of the screen to open the app drawer.
    • Tap on the "Settings" app
  2. Navigate to Honeywell Settings:

    • Scroll down and tap on "Honeywell Settings".

 

    • Select "Scanning".


3. Configure the Internal Scanner:

    • Tap on "Internal Scanner".
    • Select "Default Profile".
    • Go to "Data Processing Settings".

 


(1) Check the check box "Wedge"

(2) "Wedge Method":  Standard

(3) "Suffix"

  • In the "Suffix" field, enter \x09 to add a tab after each scan (the hexadecimal code for the tab character).
  • Tap "OK" to save the changes

Info

if firmware updates that might add the "Postamble" option, then the steps for Set the Suffix to be replace by Set the Postamble.

Set the Postamble:

    • In the "Postamble" field, enter \t to add a tab after each scan.
    • Tap "OK" to save the changes.


Save and Exit:

    • Tap the back button until you exit the settings.

These steps should configure your Honeywell device to automatically insert a tab after each barcode scan